Matters needing attention for wiring harness maintenance of medical instruments and equipment

Date: 2021-03-30 Visited: 462

At present, the maintenance of medical equipment is a very complicated work, many medical institutions have equipment department, responsible for maintaining the safety and stability of equipment, but there are many problems that many equipment maintenance personnel do not understand or pay attention to. Here to everyone under the medical equipment wiring harness maintenance and maintenance.


The first point: meticulous daily maintenance, to ensure the normal operation of equipment is crucial.


Daily maintenance seems simple, but many times is not paid attention to, but also easy to ignore; But a lot of times big problems are compounded by small problems. To do with the clinical use of active cooperation, keep the surface of the instrument clean; Check whether the voltage and power supply are normal before use; During use, observe whether the function of the instrument is normal and fill in the use record. Develop good habits during routine maintenance to avoid damage.


Second point: equipment maintenance work, must be carefully handled, do not careless.


In case of equipment failure, information collection and preparation work should be done before maintenance. Including the model number, factory number, time of fault occurrence, abnormal sound when the fault occurs, whether there has been sudden power failure, whether the instrument has moved and other issues.


During maintenance, attention should be paid to the sequence of disassembly of medical equipment and do not force disassembly with brute force. Disassembled fastening screws, small pieces, etc., can not be conveniently placed, to be classified to avoid loss. After the completion of equipment maintenance, installation, and then in reverse order step by step to restore the original, no redundant accessories. The damaged parts should also be marked and restored to their original appearance after replacement, without any mistakes.


After the maintenance work is completed, clean the surface of the instrument, connect the power supply, to see if it can work normally. Calibrate the instrument to return to normal working state, and then hand it over to the user for trial to check whether the instrument is restored to the original working state, so as to avoid leaving hidden dangers. After cleaning the site, check whether there are missing tools, and fill in the maintenance log for future reference.


The protection engineer in maintenance should always pay attention to the protection work when maintaining the instrument, whether it is leakage or cross infection and other problems, should pay attention to the protection. Don't cause unnecessary injuries.


Third point: regular maintenance inspection, problems found as soon as possible, as soon as possible to solve.


Detailed preventive maintenance should include:


Appearance inspection: first of all, check whether the buttons, switches, joints and sockets of the instrument are loose and misplaced, whether the contact of plugs and sockets is oxidizing, rusting or poor contact, whether the power line is aging, whether the heat dissipation and exhaust air are normal, whether the connection of all kinds of grounding and pipe is good.


Cleaning and maintenance: it is to clean the electrical and mechanical parts of the surface and the internal parts of the instrument, including cleaning the filter screen and the relevant pipes, cleaning the relevant plugs and sockets of the instrument, to prevent bad contact, and lubricating the necessary mechanical parts.


Replacement of wearing parts: to have reached the service life and performance decline, substandard components or parts required to be replaced regularly as specified in the operation manual to timely replace, to prevent the possible expansion of the fault or cause the machine failure. In the case of insufficient battery charging, the relevant personnel should be urged to charge regularly, and all kinds of obvious and potential faults of the equipment should be eliminated.


Performance test calibration: test the voltage stability value of each DC power supply, the voltage value or waveform to be tested in the circuit, and make necessary calibration and adjustment according to the requirements of the manual, in order to ensure that the technical indicators of the instrument meet the standards, to ensure the quality of the instrument in medical diagnosis and treatment.


Safety check: 1. Check whether the frame is firm, whether the mechanical operation is normal, and whether the connecting parts are loose, fall off or rupture. 2. Check whether various leads, plugs and connectors are damaged, whether the grounding wire is firm, and whether the grounding resistance and leakage current are within the allowable limit.

Contact us

ComHuge (Dongguan) Medical Wire Harness Technology Co., Ltd

Hotline: +86-13929208661

Learn more

Feedback

© 2020-2021 ComHuge (Dongguan) Medical Wire Harness Technology Co., Ltd All Rights Reserved.   Powered by: ytclouds.net
主站蜘蛛池模板: 成人在线观看 | 精品国产一区久久哟 | 国产精品无码mv在线观看 | 伊人天天躁夜夜躁狠狠 | 日本动漫在线免费观看 | 91看片无限制版下载v1.2.1 | 中文字幕aav| 国产日韩综合一区二区性色av | 91在线无精精品秘一区二区 | 自拍偷在线精品自拍偷免费 | 欧美一级大片在线观看 | 91尤物在线精品无 | 亚洲乱码 | 免费国产在线观 | 日韩欧美精品视频在线 | 91久久人人| 极品熟妇大 | 香蕉视频污下载 | 日本三级韩国三级欧美三级 | 中日韩精品视频在线观看 | 精品视频午夜一区二区 | 精品亚洲成a人无码成a在线观看 | 亚洲欧美日韩久久精品 | 亚洲精品成人片在线播放 | 精品无码国产自产拍在线观看蜜 | 91人妻人人澡人人爽人人爽 | 欧美大片免费观看 | 欧美国产另类首页 | 无码少妇一区二区三区芒果 | 亚洲一区二区在线播放 | 日韩精品1区| 呦系列视频一区二区三区 | 欧美日韩亚洲二区在线 | 又爽又黄有又色的视频 | 欧美日韩一区二区三区不卡资源丰富 | 亚洲欧美自拍制服另类图区 | 狠狠色噜噜狠狠狠狠av不卡 | 末发育女av片一区二区 | 国产日产欧美一区二区 | 91人人双人人妻人人澡 | 国产免费不卡av在线播放 |